Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

hbp-22_profile-left_600px
hbp-22_profile-left_600pxhbp-22_front_600pxhbp-22_profile-right_600px

Model HBP-22

Body Contamination Monitor

 

Features

  • Intuitive User-Friendly Software
  • Large Service Space in a Footprint of 900 x 840 mm (35.4 x 33.1 in.) (W x D) with Easy Access to the Service Cabinet
  • Modern 12 in. Touch-Screen Display
  • Stainless Steel Housing for Easy Cleaning and Durability
  • Access to Ludlum's Test Tool Software for Detector Analysis
  • Export of Measurement/Parameter Data in XML Format via USB
  • Access to Historical Measurement Data via Integrated Database
  • Network Capability for Remote Monitoring

Robust, Ergonomically Designed Body Contamination Pre-Monitor

The Model HBP-22 is a body contamination monitor that utilizes beta plastic detectors to measure personnel as a pre-monitor. Robust, with a modern design that integrates the latest available industrial technology, the system is optimized for users of all sizes.

The key features include:

  • 22 beta plastic detectors with semiconductor readout
  • Whole body measurement in 2 easy steps
  • Automated measurement process with audio-visual user guidance
  • Integrated 12 in. touch-screen display
  • Intuitive user-friendly software
  • Hand-detector on the side
  • Latest industry-controller technology
  • Energy filter settings to optimize discrimination of background radiation
  • Power provided by internal UPS for several measurements during power loss

 

  • Specifications
  • Options
  • Documents
  • Specifications
  • Options
  • Documents

Specifications

Standards The monitor is compliant with the following standards:
IEC61098, CE, CSA / UL or EMC, ISO11929
Detectors 22 beta plastic detectors
Active area (per 2-step measurement): 10,648 cm2 (1,650 in2)
User Software Automated measurement process with voice guidance for users. Web based for easy RP office access.
Sensors 1x foot, 1x torso, and 1x hand
Electronics Monitor status indicated with LED lights
Housing Aluminum frame with stainless steel housing
External Dimensions
(H x W x D)
2195.5 x 900 x 840 mm (86.4 x 35.4 x 33.1 in.)
Weight Standard, incl. back wall: 220 kg (485 lb)
Power Supply 110 - 230 V, 0.7 A, internal uninterruptable power supply

Options

A range of additional options are available to enhance the capabilities of the monitor and to customize the instrument to your specific needs. Example options include:

  • Alpha discrimination by ZnS detectors
  • Dosimeter and card reader integration
  • Configuration as check-in monitor or nuclear medicine/PET monitor possible with beta-gamma hybrid detectors

Documents

  • Data Sheet

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.