Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3030_face
m3030_facealpha_beta_sampl_4b38e9bc4377d3030_control_software

Model 3030

Alpha-Beta Sample Counter CE Label

Part Number: 48-3204

Features

  • Fully Integrated Alpha-Beta Sample Counter
  • Simultaneous Alpha and Beta Counting
  • Shielded 5.1 cm (2 in.) Diameter Sample Tray
  • Independent Readouts
  • CPM & DPM Modes
  • Background Subtraction
  • Alpha/Beta Alarms
  • QC Check
  • 8 Hour Battery Operation
  • Real Time Clock
  • RS-232 Interface
  • Includes PC Software

The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS(Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. This combined system supplies independent backlit LCD readouts to support discriminated alpha and beta sample counting. Key features include background subtraction, crosstalk correction, separate alpha/beta alarms, cpm/dpm operating modes, and a pre-scripted QC function with automatic reminder timer.

The instrument supports both 110 and 220 Vac operation, and includes a trickle charged gel-cell battery for portable offsite use for up to eight hours. A wide-range high voltage power supply supports virtually any detector. Status indicators located along the front panel inform the operator when a QC check is required, if the detector is non-functional, if it is operating in dpm or cpm mode, and if either an alpha or beta alarm setpoint has been exceeded.

The count time is selected via a front-panel rotary switch that enables count times ranging from 0.1 to 60 minutes, or some other prescribed value as set up via a link to a PC. Other controls include a start count button, audio volume rotary adjustment, and instrument on/off switch. An RS-232 output from the rear panel supports connection to either a printer or PC. Included in the price is PC-control software, which is a Windows application that supports setup of the system, as well as collecting and logging all count results from the 3030.

 

  • Specifications
  • Options
  • Documents
  • Software
  • Video
  • Specifications
  • Options
  • Documents
  • Software
  • Video

Specifications

Indicated Use Simultaneous alpha-beta sample counting   
Detector ZnS(Ag) adhered to plastic scintillation material
Tube 5.1 cm (2 in.) diameter magnetically shielded photomultiplier
Window 0.4 mg/cm2 aluminized mylar
Active and Open Area 20.3 cm2
Sample Holder Brass housing with nickel plated brass sample tray capable of holding up to a 5.1 cm (2 in.) diameter sample
Shielding Thickness: 19 mm (0.750 in.)
Alpha Efficiency (4π) 239Pu 37%
230Th 32%
238U 39%
Beta Efficiency (4π) 14C 8%
99Tc 27%
137Cs 29%
90Sr/90Y 26%
Cross Talk Alpha to Beta ≤ 10%
Beta to Alpha ≤ 1%
Background Alpha  3 cpm or less
Beta-Gamma typically 50 cpm or less (10 μR/hr field)
Audio Built in unimorph-type speaker with volume control to provide a dual tone click-per-event audio
Status Indicators
  • Backlit indicators for daily QC check needed (QC)
  • Overload condition (OL)
  • Counting in cpm or dpm mode (CPM/DPM)
  • Count has exceeded alpha alarm set point (αAL)
  • Count has exceeded beta alarm set point (βAL)
Scalers Two each six-digit LCD displays with backlights providing a range of 0 to 999999 counts
Scaler Linearity Reading within 2% of true value
Count Timer Settings 0.1, 0.5, 1, 2, 5, 10, and 60 minutes. PC position facilitates other user-defined values set by software program.
High Voltage Adjustable from 200 to 2500 Vdc
Thresholds Alpha -120 mV
Beta -4 mV
Beta Window 50 mV
Data Output 9-pin RS-232 port for connection to PC for data download and adjustment of setup parameters. A one meter RS-232 to USB adapter cable is included. PC interface software is available for download here.
Power 250 watts at 95 to 250 Vac, 50–60 Hz single phase
Internal 12 Vdc, 1.2A/hr, trickle charged battery provides power up to eight hours.
Construction Aluminum housing with gray powder coat paint and sub-surface printed front panel
Temperature Range -20 to 50 °C (-4 to 122 °F)
Size (H x W x L) 29.2 x 19.1 x 26.7 cm (11.5 x 7.5 x 10.5 in.)
Weight Approximately 13.2 kg (29 lb)
Software Computer based software to perform setup and calibration routines including: background subtract, crosstalk correction, cpm/dpm modes, daily QC check parameters, alarm levels, and automatic plateaus.
All parameters are stored in the instrument in non-volatile memory. The supplied software is capable of logging and storing the following: Sample Number, Sample Date, Sample Time, Alpha Count, Beta Count, Sample Type, Comments.

 

Options

OptionDescriptionPart Number
model_4167-386
Printer
Printer with power adapter, printer paper, cable, and driver software CD. 4167-386
planchets_group
Sample Planchets
Set of 500 aluminum or stainless steel sample planchets. Depends on material.

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate

Software

PC interface software and the driver needed to use the RS-232 to USB adapter cable are available for download on the Software & Firmware Downloads page.

 


Video

Model 3030 Overview


Related Products

m3030-2-face
Model 3030-2
m3030p-lft2
Model 3030P
Results 1 - 2 of 2

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.