Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Emergency Response

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Portal Monitors

No subcategories

Isotope Identifiers

No subcategories

Personal Radiation Meters

No subcategories

Friskers

No subcategories

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3002_frontrtangleview_500
m3002_frontrtangleview_500m3002_frontfaceview_1565361796m3002_frontlftangle-viewmodel_3002_top-angle

Model 3002

Alpha-Beta Digital Survey Meter 

Part Number: 48-4037

Features

  • Large Backlit LCD for Ease of Reading
  • Auto Ranging, Dual Tone Audio Clicks
  • All-Digital Calibration
  • Alpha, Beta, or Alpha + Beta Measurements
  • Rate, Max, and Count Modes of Operation
  • 4-Button Intuitive Interface for Easy Operation
  • Lighter Weight Yet Ruggedly Built
  • Splash-Resistant Construction for Outdoor Use

The Model 3002 is a durable, lightweight instrument designed for alpha and beta radiation survey with an external detector. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash resistant construction allows the instrument to be used outdoors.

Three modes of operation are available – RATE, MAX, and COUNT – which can be selected by pressing the MODE button. Measurements can be collected in cps, cpm, Bq, or dpm units. Pressing the α-β button switches between alpha, beta, or alpha+beta measurements. When enabled with the optional Lumic Data Logger Kit (see Options), data can be logged in any of the operational modes using the LOG button on the handle. Up to 1000 data points can be stored internally.

Instrument setup can be done either through the front-panel controls or via the Lumic Calibration Kit (see Options). The Model 3002 is shipped ready to use with batteries and calibration certificate.

 

  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video

Specifications

Compatible Detectors alpha-beta scintillation or gas proportional
Display 3-digit auto-ranging LCD with large 20 mm (0.8 in.) digits.
Units: (k)cps, (k)cpm, (k)Bq, (k)dpm.
Indicators: bar graph, radiation type (alpha (α), beta(β)), MAX, ALARM, USB, audio, low-battery
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 Bq to 99.9 kBq
  • 0.00 dpm to 999 kdpm
Operational display ranges are dependent on the detector and dead time configuration. The minimum and maximum display can be set to limit the display to the calibrated range.
Linearity Within 10% of true value
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-On (will reduce battery life)
User Controls
  • ON/OFF: Extra-long press to turn ON; short press to acknowledge alarms; extra-long press plus 3 seconds to turn OFF
  • α-β: Short press changes between alpha, beta, and alpha + beta measurements
  • AUDIO: Short press to adjust audio level, long press in COUNT mode allows for selection of alternate count times
  • MODE: Short press alternates between available modes: RATE (displays count rate), MAX (captures peak rate), and COUNT (captures rate or dose readings for a user-selectable preset count time from 0 to 10 min)
  • LOG: Short press to log current display (requires Lumic Data Logger Kit, see Options), or initiate count in COUNT mode)
Response Time User-selectable from 1 to 60 seconds, or auto-response rate FAST or SLOW
Alarms Two adjustable count rate, exposure/dose, and count alarm setpoints adjustable over the display range
Overload Protection High count rate saturation protection prevents false display of lower count rates. "OL" will appear on display and an audio warning will be triggered.
Loss of Count Protection After a user-settable time interval (default 60 seconds) of no pulses from detector, unit will flash a zero reading and the alarm audio will be triggered
Overrange If the reading should exceed the predefined detector range, the instrument will flash a maximum reading and trigger an audio warning.
Dead Time Correction Employs first and second order corrections for extended performance
High Voltage 400 to 2200 Vdc
Threshold Alpha: -2 to -500 mVdc
Beta: -2 to -99.9 mVdc
Audio Approximately 4.5 kHz, click audio greater than 65 dB at 0.6 m (2 ft), alarm audio greater than 72 dB
Power Four alkaline “AA” batteries
Battery Life Approximately 750 hours of operation (as low as 100 hours with backlight configured for continuous-on), 16-hour low battery warning
Construction High-impact plastic with water-resistant rubber seals and separate battery compartment
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 5 or IP rating of 53
Size (H x W x L) 16.5 x 11.4 x 21.6 cm (6.5 x 4.5 x 8.5 in.)
Weight 0.7 kg (1.6 lb) (excluding detector and clip)

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Lumic Data Logger Kit
(Model 3000-Series)
Includes Lumic Data Logger Software and cable. 4498-1019
RS232 serial optionRS-232 Serial Port Adds a true RS-232 serial port connector. 4519-490
TTL serial optionTTL Serial Port Adds TTL 3.3 V serial port connector. Available modes are instrument dependent, contact us for more information on configuration options. 4519-155
Headphone Jack
Adds a headphone jack to the instrument. 4498-555
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
M3000 Series with Strap
Shoulder Strap
1.8 m (6 ft) adjustable nylon shoulder strap. Requires instrument case modification. 4498-868
m2312958_open
Model 3000-Series Case
Rugged, dust- and waterproof transport and storage case. 2312958

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate
  • Model 3000 Series Comparison Table
  • Options for Model 3000 Series

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Video

Model 3002 Device Menu Overview


Related Products

m3003_web
Model 3003 Series
m3000_angle1
Model 3000
m3001_face_w_log-button--handle-1b
Model 3001
m3014
Model 3014
m2360-lft-angle-trans_500px
Model 2360
Results 1 - 5 of 5

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.