Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form

m329-32_rightcorner
m329-32_rightcornerm329-32_rightside

Model 329-32

Laundry Contamination Monitor

Part Number: 48-2113

Features

  • Highly Automated System
  • Simultaneous Monitoring of Upper and Lower Surfaces
  • Lockable Caster Wheels
  • 32 Alpha and 32 Beta-Gamma Channels
  • Audible Alarm is Accompanied by Visual Indicator LEDs for Indicating Approximate Location of Contamination
  • Real-Time Performance Status LEDs
  • Pass-Through Tunnel Adjusts Up to 17.8 cm (7 in.) Height

The Ludlum Model 329-32 Laundry Contamination Monitor is intended for automatic monitoring of both alpha and beta-gamma contamination on clothing or other light articles presumed to be free of radioactivity, or within release or reuse limits. A motor-driven steel-mesh conveyor belt carries articles between two gas proportional detector arrays. An audible alarm will sound when contamination exceeds the given alarm setpoint. A LED array spanning the belt shows the approximate position of the alarm on the conveyor, and provides the operator with the status of the machine. A dual LCD shows the counts and the current operating conditions, such as conveyor speed and gas flow. A security-code protected 20-key keypad also allows the changing of alarm set points, operating parameters, and other system information. The entire system is mobile, with lockable casters to prevent unwanted movement of the monitor.

Each lower and upper detector array has 16 individual gas proportional detectors, providing 32 alpha channels and 32 beta-gamma channels for a total of 64 counting channels. A spare detector array (supplied with each system) allows for easy replacement, reducing down time. The detector arrays are staggered providing an even response across the conveyor. The usable detection width is 86.4 cm (34 in.) with an overall belt width of 91.4 cm (36 in.).

All three detectors (upper, lower, and spare) slide out of the conveyor bed for cleaning and repair. The electronics is microprocessor-based, and housed in two slide-out drawers. There are two alarm levels, each fully adjustable. The first alarm level (ALERT) can pause the conveyor, stop the conveyor, allow the conveyor to continue, or re-scan. Re-scan reverses the belt to clear the probe that caused the alert, and then passes the article through the monitor again. A master yellow alert lamp will light for the duration of any ALERT. The second alarm level (ALARM) can either stop the conveyor and light the red master lamp and audio, re-scan once, twice, always, or it may continue conveyor operation and latch all alarms. Fail detection features include high-voltage failure, low count, and high background. The high voltage, conveyor belt speed, and output gas flows are monitored by the central processor. Pressing the BACKGROUND UPDATE button manually enters the background mode. Automatic background updates allow updating after the conveyor has become free of articles.

 

  • Specifications
  • Documents
  • Specifications
  • Documents

Specifications

Application Clothing and light article scanning
System Control Panel Two 40-character wide by 8-line LCD displays with back lights and 20-key control pad (provides count readings for each channel as well as system parameter information and control)
Detector Arrays Two arrays (one on top, one on bottom), each of sixteen 100 cm2 (15.5 in2) gas proportional detectors in two staggered rows of eight, providing a 86.4 cm (34 in.) wide continuous detection area
Spare Array A spare array is stored under unit and connected to gas for quick replacement if necessary.
Recommended Counting Gas P-10 (10% methane, 90% argon)
Detector Window 0.4 mg/cm2 aluminized polyester
Array Area (each) Active ~ 2000 cm2 (310 in2)
Open ~ 1600 cm2 (248 in2)
Efficiency (4π) 90Sr/90Y ~ 22%
230Th 15%
High Voltage Adjustable from 200 to 2500 V
Threshold Alpha 125 mV
Beta-Gamma 2.5 mV
Beta-Gamma Window 50 mV
Background Update Can be done manually or automatically when no articles are on conveyor belt
Count Time Adjustable from 1 to 12 seconds
Article Size Maximum 17.8 x 86.4 cm (7 x 34 in.) (W x H). Upper conveyor adjustable from 0 to 17.8 cm (0 to 7 in.) above lower conveyor.
Automatic Re-Scan Feature allowing for automatic reverse and re-scan of articles when alarm is indicated
Count Rate Alert Adjustable from 0 to 9999 cps (indicated by yellow lamp and LEDs on operator panels)
Count Rate Alarm Adjustable from 0 to 9999 cps (indicated by red lamp and LEDs on operator panels)
Audio 2 unimorph-type speakers that are used to indicate the alarm conditions (greater than 68 dB at 0.61 m [2 ft])
Acknowledge Pushbutton to silence audio
Serial Port Allows for output to printer
Conveyor Belts Two (one upper, one lower) 91.4 cm (36 in.) wide stainless steel woven mesh belts (80% open)
Conveyor Speed Adjustable from 0.25 to 14 cm/s (0.1 to 5.5 in/s)
Run Green pushbuttons on operator control panels and side of unit to start conveyor
Stop Red pushbuttons on operator control panels and side of unit to stop conveyor
Reverse Yellow pushbutton on side of unit to reverse conveyor
Emergency Stop Conveyor is encircled by pressure-sensitive bump bar to automatically stop conveyor when touched
Power 95 to 135 VAC (220 VAC available)
Construction Steel frame and aluminum electronics housing
Temperature Range -15 to 50 °C (5 to 122 °F)
Size (H x W x L) 150 x 116 x 282 cm (59 x 45.8 x 111 in.)
Weight 250 kg (550 lb)
Shipping Size (H x W x L) 152 x 122 x 301 cm (60 x 48 x 119 in.)
Shipping Weight 568 kg (1250 lb)

Documents

  • Data Sheet
  • Operator's Manual
  • Technical Manual

Related Products

hlm-6_web
HLM-22, HLM-3G
HLM-6GP
HLM-6GP
Results 1 - 2 of 2

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.