Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form

m2241-2rk_a_left_angle
m2241-2rk_a_left_anglem2241-2rk_b_frontm2241-2rk_c_right_angle

Model 2241-2RK

Emergency Response Kit CE Label

Part Number: 48-2829

Features

  • Ready-to-Go Kit
  • Measures Alpha-Beta-Gamma Contamination
  • Measures Exposure Rate
  • Includes a High-Sensitivity Gamma Probe for Quickly Finding Sources
  • Auto-Ranging Digital Scaler-Ratemeter

The 2241-2RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the digital, auto-ranging, and versatile Model 2241-2 Scaler-Ratemeter that can measure exposure, contamination, and samples. Responders can either plug in the Model 44-9 alpha-beta-gamma GM pancake probe for contamination measurements and measuring samples, or the Model 44-2 high-sensitivity gamma scintillation detector for locating the source of high readings. A locked toggle switch selects the correct set of operating parameters for the detector currently connected to the instrument to optimize the measurement. A 137Cs check source is included to verify proper operation of the instruments along with a check source holder for convenient and secure accessibility. The rugged transport and storage case is foam-padded with cutouts in for each device and gives air- and watertight, corrosion-proof, and padlockable protection.

Ludlum offers several versions of pre-packaged response kits suitable for a wide variety of applications. If you desire more or different detectors, or other changes to our standard kits, please contact us regarding a customized kit. 

 

  • Specifications
  • Options
  • Documents
  • Specifications
  • Options
  • Documents

Specifications

m2241-2_bb-trans_500px
Model 2241-2
Scaler-Ratemeter

m44-2
Model 44-2
Gamma Detector

m44-9_profile
Model 44-9
Alpha-Beta-Gamma Detector

cs-137_0_25microci
Plastic Disk Check Sources


check-source-holder-closed
Mechanical Check Source Holder


Case Size & Weight

Size (H x W x L) 46.5 x 35 x 17.8 cm (18.3 x 13.8 x 7 in.)
Weight 5.9 kg (13 lb) (with instruments)

Options

OptionDescriptionPart Number
m3000-series-shoulder-strap
Shoulder Strap
Adjustable nylon shoulder strap. 4363-413
Headphone Jack
Adds headphone jack to instrument. 4464-464
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
m2002-1050ambdosefilter
Dose Filter
The GM pancake detector has a significant over-response at lower energies, producing dose measurement errors. The dose filter flattens the response to within ± 20% referenced to 137Cs (662 keV) over the energy range of 20 keV to 1.2 MeV. 2002-1050

Documents

  • Data Sheet
  • Product Manual
  • PC Data Logging Software
  • PC Data Logging Software Data Sheet
  • CE Certificate

Related Products

emergency_respon_4b90241f8728b
Model 14C-RK
medical_env__res_4c44a8bbbacf5
Model 2241-3MERK
m3-is_norm_kit
Model 3-IS NORM Kit
m2241-3rk2_open_front
Model 2241-3RK2
m3001-2rk_-_rev
Model 3001-2RK
m3001-3rk2_-_rev
Model 3001-3RK
Results 1 - 6 of 6

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.