Menu
Toggle navigation
Filters
Products
Portable Survey Meters
Friskers
General Purpose - Digital
General Purpose - Analog
Computerized
Data Loggers
Specialized Meters
Geiger Counters
Intrinsically Safe
Ion Chambers
Isotope Identifiers
microR / microSv Meters
Extended Reach microR / microSv Meters
Neutron Meters
Pocket-Size Meters
Scaler-Ratemeters
Stretch Scopes
Personal Radiation Meters
No subcategories
Benchtop Meters
No subcategories
Scalers / Counters
No subcategories
Pulsers
No subcategories
Detectors
Alpha
Alpha-Beta
Alpha-Beta-Gamma
Beta
Gamma GM
Gamma Scintillator
Low-Energy Gamma Scintillator
Neutron
Waterproof Detectors
Pipe Detectors
Sample Counter Heads
Sample Holders
Monitoring Systems
Area Monitor Controllers
Area Monitoring Systems
Portal Monitors
Monitoring Systems
Contamination Monitors
Article Monitors
Air Monitors
Hand & Foot Monitors
Body Monitors
Vehicle Monitors
Scrap Monitoring Systems
Laundry Monitors
Ground/Floor Surveying
No subcategories
Sample Counting
Sample Counting Systems
Scalers / Counters
Sample Counter Heads
Protean Instrument Alpha-Beta Counting Systems
Tritium Monitoring
No subcategories
NORM Kits
No subcategories
Dosimetry
Dosimeters
Dosimeter Accessories
Accessories
Detector Accessories
Handles & Straps
Audio
Cables, Connectors & Signal Converters
Check Sources
Instrument Cases
Medical Physics
Radiation Safety QA
Imaging QA Test Tools
CT / MRI QA
Mammography QA
Nuclear Medicine QA & Safety
Emergency Response Kits
General Response Kits
Medical Response Kits
Decontamination Kits
Model 44-3
Gamma Detector
Part Number: 47-1533
Specifications
Options
Documents
Replacement Parts
Specifications
Options
Documents
Replacement Parts
Specifications
Indicated Use
125
I and low-energy gamma survey
Detector Type
NaI(Tl) scintillator, 2.5 cm (1 in) dia. x 0.1 cm (0.04 in) thick
Window
18.4 mg/cm
2
Window Area
Active:
5 cm
2
(0.8 in
2
)
Open:
5 cm
2
(0.8 in
2
)
Efficiency (4π)
125
I:
33.5% (derived from
129
I efficiency)
129
I:
18%
Typical Sensitivity (
125
I)
675 cpm per µR/hr
Typical Background
(10 µR/hr field)
300 cpm
Recommended Energy Range
10 to 60 keV
Energy Response
Energy dependent (see
Energy Response Curve
)
Photomultiplier Tube
3.8 cm (1.5 in) diameter
Operating Voltage
500 to 1200 V (typical)
Connector
Series "C"
Construction
Aluminum housing with beige powder coat
Size (D x L)
5.1 x 17.8 cm (2 x 7 in)
Weight
0.5 kg (1 lb)
Options
Option
Description
Part Number
Model 180-1
Sample holder for 5.1 cm (2 in.) max. diameter samples.
47-1675
Model 180-1L
Sample holder with lead shielding for 5.1 cm (2 in.) max. diameter samples.
47-2988
Model 180-24
Sample holder for 5.1 cm (2 in.) max. diameter samples.
47-2631
Detector Collimators
Lead collimators.
Various.
Sample Planchets
Set of 500 aluminum or stainless steel sample planchets.
Depends on material.
Documents
Data Sheet
Manual - English
Manual - Spanish
CE Certificate
Energy Response Curve
Detector Clips
Replacement Parts
Description
Part Number
Window Assembly
4002-380
Mylar Window
2002-379
NaI(Tl) Scintillator
2002-361
1.5 in. PMT, Non-Based with Voltage Divider
4002-510
Red Protective Cap
03-5475
Related Products
Model 44-17
Results 1 - 1 of 1