Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m4901-may3-07c

Model 4901P

Beta-Gamma Hand & Foot Monitor CE Label

Part Number: 48-3009

Features

  • Affordable
  • Simple to Use
  • Automatic Background Subtract
  • Password-Protected Parameters
  • Alarm Audio Volume Adjustment
  • Non-Volatile Memory Requires No Battery Backup

The Model 4901P Beta-Gamma Hand & Foot Monitor is intended for use as a medium-level beta and gamma contamination monitor. Four count channels are in the standard configuration for monitoring the palm of each hand and the sole of each foot. The Model 4901P employs a total of twenty-two pancake Geiger-Mueller (GM) type detectors, five in each hand detector (palm side only) and six in each foot detector. LED indicators show status and alarm location. The Model 4901P allows parameter updating by viewing the built-in, 16-character LCD display. Detector counts, background, alarm set points, and all parameters may be viewed on the LCD display. Switches at each hand detector initiate an interrogation (both switches must activate). Audible alarm and status change indications are standard.

 

  • Specifications
  • Documents
  • Replacement Parts
  • Specifications
  • Documents
  • Replacement Parts

Specifications

Indicated Use Personnel monitoring
Detectors Pancake-type, halogen-quenched GM
Window 1.7 ± 0.3 mg/cm2 mica
Energy Response Energy dependent
Hands

10 (five per hand) pancake GM detectors
Active Area Approximately 155 cm2 (24 in2)
Open Area Approximately 122 cm2 (18.9 in2)
Efficiency 14C 3%
99Tc 12%
137Cs 12%
Shoes 12 (six per shoe) pancake GM detectors
Active Area Approximately 185 cm2 (28.7 in2)
Open Area Approximately 146 cm2 (22.6 in2)
Efficiency 14C 3%
99Tc 10%
137Cs 10%
Audio Built-in, unimorph-type speaker (greater than 68 dB at 0.6 m [2 ft])
Alarm Indicated by red LED and audible signal (each hand and shoe area has alarm indicators)
Counting Capacity 9999 counts per minute
Count Time Adjustable from 1 to 99 seconds
Alarm Hold Time Adjustable from 1 to 99 seconds
Background Accumulate Time Adjustable from 1 to 99 seconds
Background Update Interval Adjustable from 1 to 99 minutes, system will automatically update background if instrument is not in use
Force Update Timed function to force background update if regular update interval is exceeded
Status Indicators Ready Green LED, indicates instrument is ready to monitor personnel
Counting Green LED, indicates count is in process (activated by switches on hand probes)
Check OK Green LED, indicates person being monitored is clean
Short Count Yellow LED and continuous audible beep, indicates user has released hand switches before count is complete or count is attempted during background update
Power 95 to 135 Vac (178 to 240 Vac available), 50/60 Hz
Temperature Range 0 to 50 °C (32 to 122 °F) (LCD limits temperature range)
Size (H x W x L) 101.6 x 74.9 x 38.1 cm (40 x 29.5 x 15 in.)
Weight 20.5 kg (45 lb)

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate
  • Ludlum Hand & Foot Monitor Comparison Table

Replacement Parts

DescriptionPart Number
GM Tube 01-5050

Related Products

m4906a_frontview
Model 4906A
m4906ab_maybe_635344413
Model 4906AB
m4906a_frontview_1536763829
Model 4906P
Results 1 - 3 of 3

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.