Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m9dpstar_700px_1156343794
m9dpstar_700px_1156343794Model 9DP*Model 9DP*Model 9DP*

Model 9DP*

Ambient Dose Ion Chamber

Part Number: 48-3942

Features

  • Provides ICRU-Based Ambient Dose Equivalent Measurements
  • Range: Background to 50 mSv/h (5 rem/h)
  • Shows Dose Rate & Either Integrated Dose or Peak Dose Rate
  • Ambient Equivalent Dose or Dose Rate is Flat within 20% from 40 keV to 1.3 MeV
  • Sunlight Readable Color Display
  • Auto-Zeroing & -Ranging
  • Rechargeable Batteries
  • Audio & Visual Alarms
  • Data Logging
  • USB Connectivity
  • Free Firmware Updates Through Website

The Model 9DP* is a digital, hand-held pressurized ion chamber that provides highly sensitive ambient dose equivalent measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Ambient dose equivalent is defined as the dose equivalent readout that would be measured at a (human) tissue depth of 10 mm. The Model 9DP* measures and displays the ambient dose equivalent in accordance with the ICRU (International Commission on Radiation Units) 30 cm tissue equivalent sphere. This requires a special ion chamber that can provide a conversion of the (air kerma) exposure rate to provide the ambient dose and dose rate.

Measurements and instrument status are displayed on a large, 232K-color, backlit LCD screen. The screen displays the current dose rate as well as simultaneously displaying either the integrated dose rate or the peak dose rate in Sv, R, Gy, or rem units.

The instrument is operated using the four push-buttons below the screen (ON/OFF, FUNCTION, AUDIO, ACK/RESET). In addition to the visual display, click audio proportional to the current exposure rate audibly indicates the exposure rate level. Two alarm levels can be set to alert the user whenever the pre-programmed level has been exceeded. Alarms are indicated on the display and by an audio tone. The instrument can also be configured for data logging. Logged data can either be stored in CSV format and written to a standard USB drive inserted in the instrument's USB port, or written directly to a Microsoft Excel spreadsheet by connecting the instrument to a computer running Ludlum's Model 9DP Logging Spreadsheet Software (see Options).

The Model 9DP parameter settings can be edited by connecting the instrument to a basic USB keyboard. Instrument setup and calibration can also be configured using the Ludlum Dimension Interface Kit, which includes the Dimension Configuration Manager Software and the required USB cable (see Options).

NOTE: This instrument is considered HAZMAT and requires HAZMAT training to ship.
Please see the instrument manual for details.

 

  • Specifications
  • Graphs
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Specifications
  • Graphs
  • Options
  • Documents
  • Firmware Updates
  • Video

Specifications

Radiation Detected Gamma & X-rays above 25 keV
Beta above 1 MeV
Energy Response Ambient equivalent dose or dose rate, flat within 20% from 40 keV to 1.3 MeV (see Graph)
Display Ranges
(auto-ranging)
  • Sv/h units: 0 - 5 μSv/h, 0 - 50 μSv/h, 0 - 500 μSv/h, 0 - 5 mSv/h, 0 - 50 mSv/h
  • R/hr units *: 0 - 500 μR/hr, 0 - 5 mR/hr, 0 - 50 mR/hr, 0 - 500 mR/hr, 0 - 5 R/hr
  • Gy/h units: 0 - 5 μGy/h, 0 - 50 μGy/h, 0 - 500 μGy/h, 0 - 5 mGy/h, 0 - 50 mGy/h
  • rem/h units: 0 - 500 μrem/hr, 0 - 5 mrem/hr, 0 - 50 mrem/hr, 0 - 500 mrem/hr, 0 - 5 rem/hr
* Users wanting to take measurements in R/hr units should see the Ludlum Model 9DP which is specifically designed to measure exposure.
Measurement Readouts Simultaneous display of rate and either the integrated value or highest (peak) rate
Minimum Display 0.01 μSv/h (0.1 μR/hr, 0.01 μGy/h, 0.1 μrem/h)
Drift Less than 0.3 μSv/h (0.03 mR/hr, 0.3 μGy/h, 0.03 mrem/h)
Chamber Volume 230 cm3 (14 in3) volume pressurized to 9 atm (117 psig ± 5 psig)
Chamber Density Chamber wall density is 601.7 mg/cm2, Can wall density is 332.5 mg/cm2. Total density of chamber + can is 934.2 mg/cm2.
Accuracy ± 10%
Response Time Ranges from 7 seconds in lowest range to under 2 seconds in highest range when measuring from 10% to 90% of final value
Display LCD with 8.9 cm (3.5 in.) diagonal, 240 H x 320 W pixels, TFT active matrix, 232k colors, 220 cd/m2, automatic sensor-controlled backlighting
User Controls 4 pushbuttons:
  • ON/OFF
  • FUNCTION (for peak rate / Integrate modes)
  • AUDIO (on/off, volume)
  • ACK/RESET (for alarm acknowledgement, meter reset, and clearing integrated dose or peak rate)
Automatic Functions Auto-ranging, Auto-zeroing, Auto LCD backlighting
Alarms Two levels of radiation alarms available, each is user programmable throughout entire readout range
Data Logging Data is stored to detachable USB drive in CSV format for easy retrieval by PC spreadsheet/database programs. Data points include date and time, rate, integrated reading, and instrument status. Logging time intervals are set by PC interface program or USB keyboard (see Options).
Audio Outputs Built-in unimorph speaker, > 60 dB at 0.6 meters (2 ft.).
Optional audio jack available for connection to an external headset. (see Options)
USB Interface Single USB 2.0 port. May be connected to:
  • A USB keyboard (with no additional USB ports, and no integrated mouse or trackpad or audio controls) to facilitate password-protected parameter changes
  • A USB memory storage device for storing logged data
  • A PC with the optional Dimension Interface Kit for parameter editing and calibration (see Options)
Warm Up Time < 1 minute when the instrument is in temperature equilibrium with the surrounding environment
Temperature Range -20 to 40 °C (-4 to 104 °F)
Humidity 0 - 95%, non-condensing
Geotropism Less than 1%
Power Eight rechargeable "AA" NiMH batteries, supplied with wall charger for direct connection to instrument
Battery Life Approximately 12 to 30 hours between charges depending on backlighting and USB usage
Construction Durable plastic with internal metal support
Size (H x W x L) 21.9 x 11.6 x 24.5 cm (8.6 x 4.6 x 9.6 in.)
Weight 1.5 kg (3.4 lb), including batteries

Graphs

Model 9DP* Ambient Dose Equivalent Energy Response
Relative to Cs-137

Model 9DP* Ambient Dose Equivalent Energy Response Curve Relative to Cs-137

Model 9DP* Angular Dependence

Model 9DP Angular Dependence Graph

Options

OptionDescriptionPart Number
dimension_interface_software
Dimension Interface Kit
Enables calibration and setup of Dimension instruments. Includes Dimension Configuration Manager software and USB cable. 4293-763
Model 9DP Logging Software
Model 9DP Logging Spreadsheet Software
Allows user to log real-time data from the instrument directly to an Excel spreadsheet.

Software + USB Cable: 4293-998

Software Only: 1370-101

Model 9DP headphone jack option
Headphone Jack
Adds headphone jack to instrument. 4293-891
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
Model 9DP Series rechargeable battery pack
Model 9DP Series Rechargeable Battery Pack
Battery pack of 8 rechargeable "AA" NiMH batteries. 4536-101
m4543-028_dimensionbatterypack
Model 9DP-Series Alkaline Battery Pack
Battery pack of 8 non-rechargeable "AA" batteries, permitting quick battery change in the field. 4543-028
10 microCurie Cs-137 source
Plastic Disk Check Sources
10 µCi 137Cs check source 01-5231
case_m2313065_med-500px
Transport & Storage Case - Medium
Rugged, dust- and waterproof transport and storage case. 2311063
m3000-series-shoulder-strap
Shoulder Strap
1.8 m (6 ft) adjustable nylon shoulder strap. Requires instrument case modification. 4536-632
Mini-USB Keyboard
USB Keyboard
Connects to instrument and can be used to configure the instrument for data logging. 2312289

Documents

  • Data Sheet
  • Product Manual
  • Model 9DP Logging Software Instructions
  • CE Certificate

Firmware Updates

Firmware updates are available for download on the Software & Firmware Downloads page under the Support Menu.


Video

Model 9DP Full Instrument Overview

 

Model 9DP Control Panel (Buttons) Overview

 

How to Decompress the Model 9DP Pressurized Ion Chamber


Related Products

m9dp_alt
Model 9DP
m9dp-1_700px_722639893
Model 9DP-1
ion_chamber_surv_4ebaaf3d06316_1315210411
Model 9DP-1*
m9-3-lt-angle-trans_500px
Model 9-3
m9-4-upright-trans_500px
Model 9-4
m9-4-upright-trans_500px
Model 9-4RF
Results 1 - 6 of 6

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.