Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

2241-4_neutron_mete_cmyk_500px
2241-4_neutron_mete_cmyk_500pxm2241-front_500px

Model 2241-4

Neutron Dose Survey Meter

Part Number: 48-2973

Features

  • 22.9 cm (9 in.) Moderated Neutron Detector
  • Range: 0 to 100 mSv/h (0 to 10,000 mrem/hr)
  • Gamma Rejection up to 0.1 Sv/h (10 R/hr)
  • Ratemeter with Built-in Scaler Function
  • Autoranging
  • Independent Adjustable Alarms for Ratemeter & Scaler Modes
  • RS-232 Connection

The Model 2241-4 is a portable neutron REM meter. This instrument combines Ludlum's microprocessor-based digital Scaler-Ratemeter Model 2241 electronics with a Model 42-31H Neutron Detector. This system is sensitive to neutrons from thermal to 12 MeV with a response approximating the inverse RPG curve for neutron dose.

Data is presented on a four-digit LCD with a moving decimal point. Two additional digits are employed for the Scaler mode. A three-position switch labeled Off/Ratemeter/Scaler selects the desired operating mode for the instrument. Other controls include Audio On/Off switch, Fast/Slow Response switch, LCD Backlight pushbutton, Count Reset pushbutton, and Scaler Count/Stop pushbutton.

This instrument incorporates independent adjustable alarms for the ratemeter and scaler operating modes. Audible alarms may be silenced (acknowledged) by depressing the RESET switch. The scaler count time, alarm values, and backlight on time are pre-programed values. This instrument can be programmed via its RS-232 port, which can also be used to output readings at two-second intervals.

Medical Application

NCRP Report #151 redefines the need to evaluate not only new Linac installations but also equipment that has been upgraded for higher energies and broader capabilities, like IMRT and rotational beam systems, which may be beyond what original shielding designs had recommended.

 

  • Specifications
  • Options
  • Documents
  • Software
  • Replacement Parts
  • Specifications
  • Options
  • Documents
  • Software
  • Replacement Parts

Specifications

Detector 3He tube (LND 25185 or equivalent)
Moderator 22.9 cm (9 in.) diameter cadmium-loaded polyethylene sphere
Measurement Range 0 to 100 mSv/h (0 to 10,000 mrem/hr)
Sensitivity (moderated 252Cf) Typically 10 cpm per µSv/h (100 cpm per mrem/hr) (bare AmBe neutrons)
Energy Response Provides appropriate inverse RPG curve for neutrons from thermal through 7 MeV, provides response up to 12 MeV
Gamma Rejection (137Cs) < 10 cpm through 0.1 Sv/h (10 R/hr)
Display 4-digit LCD with 1.3 cm (0.5 in.) height, plus two 0.5 cm (0.2 in.) digits used for overflow counter (scaler mode) and exponential powers (parameter setup)
Controls
  • Off / Ratemeter / Scaler three-position operation switch
  • Audio on/off switch
  • Fast/Slow response switch
  • LCD backlight pushbutton
  • Count reset pushbutton
  • Scaler count pushbutton on the handle
Alert / Alarm Pre-programmed alarms for ratemeter and scaler modes
Audio Built-in audio speaker with audio on/off switch, greater than 60 dB at 0.6 m (2 ft)
Scaler Time Adjustable from 1 to 999,999 s, can display seconds or minutes
Operating Voltage Approximately 1200 Vdc
Input Sensitivity -2 mV
Temperature Range -20 to 50 °C (-4 to 122 °F)
Environmental Rating IP rating of 53
Power Two each “D” cell batteries housed in an externally accessible sealed compartment
Battery Life Typically 200 hours, low battery symbol alert (instrument will operate for approximately 24 hours after symbol first appears)
Detector Connector Series “C” (others available)
RS-232 “D” type connector, used for programming instrument and outputting data at two-second intervals, baud rate from 150 to 19,200 bps
Size Meter (H x W x L): 16.5 x 8.9 x 21.6 cm (6.5 x 3.5 x 8.5 in.)
Detector (H x W x D): 26.2 x 22.9 x 22.9 cm (10.3 × 9.0 × 9.0 in.), including brackets
Weight Meter: 1.6 kg (3.5 lb) including batteries
Detector: 6.56 kg (14.5 lb)

Options

OptionDescriptionPart Number
case_web
Case for Neutron Meters
Rugged transport and storage case. 2310377
2311487-neutron-case_600px
Case for Neutron Meters
Rugged transport and storage case. Has wheels and extendable handle. 2311487

Documents

  • Data Sheet
  • Product Manual
  • Data Logging Data Sheet
  • CE Certificate
  • Ludlum Neutron Meters Comparison Table

Software

Logger and Calibrator Software is available for download on the Software & Firmware Downloads page.


Replacement Parts

DescriptionPart Number
RS-232 Cable (9-pin) 8303-458
RS-232 Cable (25-pin) 8303-459
Meter Bezel 4408-051
Digital Display 5408-259
Rolled Handle 4408-075
Flat Handle 4408-090

Related Products

m2241-left-front-angle_no-speaker
Model 2241
m30-7
Model 30-7 Series
m3007-angle
Model 3007 Series
m12-4-7_no_bkg_500
Model 12-4-7
m30-4_angle
Model 30-4
m12-4a
Model 12-4
m375-31h_pic-8-trans-a-merged
Model 375-31H
m2363-w-prescila8
Model 2363 with 42-41L
m15-lft-angle-trans-lower-detector-5-merged_500px
Model 15
Results 1 - 9 of 9

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.