| Model No. |
Alpha
|
Beta
|
Gamma
|
Neutron
|
Application |
Detector Type |
Characteristics |
| 43-1 |
x
|
|
|
|
Survey |
Scintillation, ZnS(Ag) |
83 cm2 active, 75 cm2 open |
| 43-2 |
x
|
|
|
|
Survey |
Scintillation, ZnS(Ag) |
12 cm2 active, 12 cm2 open |
| 43-5 |
x
|
|
|
|
Survey |
Scintillation, ZnS(Ag) |
76 cm2 active, 50 cm2 open |
| 43-65 |
x
|
|
|
|
Survey |
Scintillation, ZnS(Ag) |
63 cm2 active, 50 cm2 open |
| 43-92 |
x
|
|
|
|
Survey |
Scintillation, ZnS(Ag) |
100 cm2 active, 89 cm2 open |
| 43-44 |
x
|
|
|
|
Survey |
Air Proportional |
76 cm2 active, 50 cm2 open |
| 43-44-1 |
x
|
|
|
|
Survey |
Air Proportional |
154 cm2 active, 100 cm2 open |
| 43-40-2 |
x
|
|
|
|
Survey |
Air Proportional |
239 cm2 active, 188 cm2 open |
| 43-40-3 |
x
|
|
|
|
Survey |
Air Proportional |
320 cm2 active, 253 cm2 open |
| 43-1-1 |
x
|
x
|
|
|
Survey |
Scintillation, Phoswich |
83 cm2 active, 75 cm2 open |
| 43-2-2 |
x
|
x
|
|
|
Survey |
Scintillation, Phoswich |
12 cm2 active, 12 cm2 open |
| 43-93 |
x
|
x
|
|
|
Survey |
Scintillation, Phoswich |
100 cm2 active, 89 cm2 open |
| 43-68 |
x
|
x
|
|
|
Survey |
Gas Proportional |
126 cm2 active, 100 cm2 open |
| 44-7 |
x
|
x
|
x
|
|
Survey & Sample Counting |
GM, End Window |
6 cm2 active, 5 cm2 open |
| 44-9 |
x
|
x
|
x
|
|
Survey & Sample Counting |
GM, Pancake |
15 cm2 active, 12 cm2 open |
| 44-9-18 |
x
|
x
|
x
|
|
Survey |
GM, Pancake |
15 cm2 active, 12 cm2 open, telescope handle |
| 44-40 |
x
|
x
|
x
|
|
Survey & Sample Counting |
GM, Pancake |
15 cm2 active, 12 cm2 open, shielded |
| 44-88 |
x
|
x
|
x
|
|
Survey & Sample Counting |
GM, Pancake |
15 cm2 active, 12 cm2 open |
| 44-25 |
x
|
x
|
x
|
|
Hand Contamination Monitoring |
GM, Pancakes |
31 cm2 active, 18 cm2 open, 2 ea. |
| 44-26 |
x
|
x
|
x
|
|
Foot Contamination Monitoring |
GM, Pancakes |
46 cm2 active, 27 cm2 open, 3 ea. |
| 44-89 |
x
|
x
|
x
|
|
Survey |
GM, Pancakes |
62 cm2 active, 50 cm2 open, 4 ea. |
| 44-94 |
x
|
x
|
x
|
|
Survey |
GM, Pancakes |
62 cm2 active, 50 cm2 open, 4 ea. |
| 44-6 |
|
x
|
x
|
|
Survey |
GM |
Energy dependent, sliding shield |
| 44-38 |
|
x
|
x
|
|
Survey |
GM |
± 15% from 50 keV - 1.25 MeV, sliding shield |
| 44-110 |
|
x
|
|
|
Survey, Tritium Contamination |
Gas Proportional |
P-10 gas flow, 126 cm2 active, 100 cm2 open, windowless |
| 44-92 |
|
x
|
x
|
|
Survey |
Gas Sealed Proportional |
Xenon sealed, 169 cm2 active, 140 cm2 open |
| 44-1 |
|
x
|
|
|
Survey, Sample Counting |
Scintillator, Plastic |
11.6 cm2 active, 11.6 cm2 open. |
| 44-21 |
|
x
|
x
|
|
Survey, Sample Counting |
Scintillator, Plastic |
5.1 cm2 active, 5.1 cm2 open |
| 44-98 |
|
x
|
x
|
|
Survey, Sample Counting |
Scintillator, BGO |
5 cm2 active, 5 cm2 open |
| 44-142 |
|
x
|
x
|
|
Survey |
Scintillator, Plastic |
100 cm2 active, 89 cm2 open |
| 44-3 |
|
|
x
|
|
125I & X-ray Survey |
Scintillation, NaI(Tl) |
1" dia x 1 mm thick |
| 44-17 |
|
|
x
|
|
125I & X-ray Survey |
Scintillation, NaI(Tl) |
2" dia x 2 mm thick |
| 44-2 |
|
|
x
|
|
Low-level, wide energy gamma detection |
Scintillation, NaI(Tl) |
1" dia x 1" thick |
| 44-10 |
|
|
x
|
|
Low-level, wide energy gamma detection |
Scintillation, NaI(Tl) |
2" dia x 2" thick |
| 44-62 |
|
|
x
|
|
Low-level, wide energy gamma detection |
Scintillation, NaI(Tl) |
0.5" dia x 1" thick |
| 44-11 |
|
|
x
|
|
Survey, Sample Counting |
Scintillation, NaI(Tl) |
2" dia x 2" thick |
| 44-20 |
|
|
x
|
|
Survey, Sample Counting |
Scintillation, NaI(Tl) |
3" dia x 3" thick |
| Series 133 |
|
|
x
|
|
Survey, doserate |
GM, Energy Compensated |
ranges betrween 0.1 mR/h to 300 R/h |
| 42-30H |
|
|
|
x
|
Survey |
H3 Proportional |
10" dia. polyethylene sphere |
| 42-5 |
|
|
|
x
|
Survey |
Scintillator, LiI |
Accompanied with a cart holding a 2", 3", 5", 10" & 12" dia. polyethylene spheres |
| 42-41L |
|
|
|
x
|
Survey |
Scintillator, Proton Recoil |
|
| 43-9 |
x
|
|
|
|
Sample Counting, 1" dia. |
Scintillator, ZnS(Ag) |
1" dia. X 0.06" thick |
| 43-10 |
x
|
|
|
|
Sample Counting, 2" dia |
Scintillator, ZnS(Ag) |
Windowless |
| 43-10-1 |
x
|
x |
|
|
Sample Counting, 2" dia |
ZnS(Ag) adhered to plastic scintillator
|
0.4 mg/cm2 window
|
| 43-78 |
x
|
|
|
|
Sample Counting, 5" dia |
Scintillator, ZnS(Ag) |
Windowless |
| 43-78-1 |
|
x
|
|
|
Sample Counting, 5" dia |
Scintillator, Plastic |
Windowless |
| 43-78-2 |
x
|
x
|
|
|
Sample Counting, 3" dia |
Scintillator, ZnS(Ag) |
0.4 mg/cm2 window |
| 203 |
|
|
x
|
|
Assay Sample Counting |
Scintillator, NaI(Tl) |
1.5" thick lead sheilding |
| 243 |
|
|
x
|
|
Assay Sample Counting |
Scintillator, NaI(Tl) |
0.5" thick lead shielding |
| 120 |
x
|
x
|
|
|
Sample Counting, 2" dia |
Gas Proportional |
0.4 mg/cm2 window |
| 180-8 |
x
|
x
|
x
|
|
Sample Counting, 1.8" dia |
GM, End Window |
1.5" thick lead sheilding |
|